Danmarks bedste Tekstilventilation

Sports and leisure

Textile based ventilation meets the high requirements for indoor climate in buildings in sports and leisure. The solution ensures a smooth and draft-free air distribution, which creates comfort for both athletes and spectators — even in halls with high ceilings and varying levels of activity.

When ventilation makes a noticeable difference

Textile ducts are the ideal solution for heating and ventilation in sports halls. With KE Fibertec's many years of experience, you get an energy-efficient system that ensures optimal air distribution - both during daily training and in crowded stands. The entire hall, including the spectator areas, is heated and ventilated efficiently, without drafts and without compromising comfort.

Special requirements for the indoor climate in ice hockey rink

The large temperature difference between the ice surface and the surrounding air creates a risk of condensation and high moisture load on structures. Ventilation must effectively control humidity to protect the building and ensure clear views.

There is a marked difference in temperature at the ice, in the stands and under the ceiling. Without proper air distribution, ice level drag and heat accumulation under the roof can occur. With the KE DireJet, the air can be controlled 100% with nozzles and differential air volumes.

Ice hockey rinks have high energy consumption for both cooling systems and ventilation. The system must therefore be carefully dimensioned so that air volumes and air distribution support the quality of the ice without unnecessary energy loss.

Players need stable and cool air at the ice, while spectators expect comfortable temperature without drafts. Textile based ventilation can handle both needs simultaneously.

The load varies from training to matches with full stands. The management strategy must be able to adapt ventilation and air volumes according to activity and number of people in the hall.

Comfort, health and energy-efficient operation are the focus

First of all, the system must ensure adequate air exchange so that CO₂, moisture and odors are effectively removed - both during daily training and at events with many spectators.

In addition, a modern sports hall requires flexible control, so that the ventilation can be automatically adapted to changing applications - from regular training to rallies and matches with full stands, where the system is adapted according to several operating strategies.

Air must not blow directly into the playing area or create a nuisance to performers and the audience. At the same time, the temperature must be kept stable so that cold zones do not arise at the floor or heat accumulation under the ceiling.

Too high humidity can affect both comfort and building construction, while too dry air can cause inconvenience to users. The ventilation must therefore be able to be precisely regulated according to activity and load.

When experience and technique create the optimal solution

KE Fibertec has provided textile based ventilation for many different installations in sports and leisure

Materials are approved according to the latest Danish fire standards

A total solution for cooling, ventilation and heating

Layout customizable on dimensions and architecturally with multiple system and color options

Lower construction costs compared to conventional systems

Get expert advice for your next ventilation project

If you’d also like to find out more about textile based ventilation and the benefits it could bring to your next project, please feel free to send us an enquiry – with no obligation.

We’re here to offer advice and guidance on how to ensure an optimal and healthy indoor climate for your construction project. We will contact you to discuss your needs and requirements in more detail, so that we can find the best solution for your project.

Need some inspiration?

Need some inspiration?

Order the inspiration brochure today and find out all about our solutions and services – from design and systems to how we can help with maintenance.

Grazie! Your submission has been received!
Oops! Something went wrong while submitting the form.

FAQs

Do you have any more questions? Write to us.

Find answers to most of what you need to know here or contact us directly for further help and guidance.

How does the system save energy and reduce operating costs?

By adding the air directly in the sub-temperature living zone, efficient heating and cooling is achieved without oversized ventilation volumes. It can reduce the energy consumption of the cooling and heating system by up to 30% and at the same time minimize the need for expensive steel equipment.

How will the solution be cheaper compared to steel ducts?

A textile based ventilation system is lighter both in the weight of the material and when assembled. This means significantly shorter assembly time - up to 9 times faster in fact. Including the assembly time, it provides significantly lower operating and construction costs than traditional steel solutions.

How do tapered nozzles provide longer throwing length and better thermal penetration?

The nozzles limit the induction of room air, so the air loses speed slower. The result is longer throwing length and deeper thermal penetration, ensuring that both hot and cold air are accurately distributed throughout the room.

What makes the hybrid solution ideal for both heating and cooling?

The hybrid solution combines dense but air-permeable fabrics with KE DireJet nozzles. It prevents condensation and dust on the ducts and ensures that both hot and cold air can be distributed efficiently and comfortably in the room.

What is industrial refrigeration?

Industrial refrigeration is a general term for refrigeration in industrial enterprises where maximum air speeds in the room are needed.